FOUNTAIN PUMP / Instruction Manual
SP450 / SP550 / SP650 / SP850 / SP900 / SP1200 / SP1500 / SP1800 / SP2200
PRINTED IN CHINA
SP112013
IMPORTANT! BEFORE YOU BEGIN:
This pump is designed for use in “clean water applications”. It is not compatible with salt water.
WARNING: SAFETY AND ELECTRICAL CONNECTIONS
The pump is supplied with 3 core electrical cable which is permanently connected and sealed to the motor. The supply cable cannot be replaced. If the cable is damaged the pump
should be discarded.
1. Pump must be connected to an approved ground fault circuit interrupter (GFCI) receptacle.
2. Do not connect to any voltage other than that stated on the pump.
3. Warning: Always unplug or disconnect all appliances from the electrical supply before putting
hands in the water, while equipment is being installed, repaired, maintained or handled.
4. Do not use the supply cable to lift the pump as this may cause damage.
5. Do not operate or leave the pump in freezing conditions.
6. Do not allow the pump to run dry. The pump must be fully submerged.
HINTS AND TROUBLESHOOTING
CAUTION: ALWAYS DISCONNECT THE PUMP FROM THE ELECTRICAL SUPPLY BEFORE
HANDLING.
If the pump operates but there is no water flow:
Make sure the pump is fully submerged.
Check the tubing for kinks or obstructions. Ensure pump outlet is clear of objects.
Check water features like spouting statues or fountain nozzles are clean and clear.
Check water inlet for any obstructions.
If normal water flow has not returned:
Remove front cover and impeller cover to access rotor area.
Rotate the rotor to ensure it is not broken or jammed. Remove the rotor to check it is free from any debris. Rinse the cover and re-assemble.
MAINTENANCE
Regular maintenance must be performed on any warranted item based upon this Owners Guide recommendations. Do not pump heated liquids, and always keep the cord away from
heat and high temperature. Connect the pump to an electrical supply with the proper voltage and fitted with a Residual Current Device.
1. Always disconnect the pump from the electrical supply before handling it.
2. Always operate the pump completely submerged. Check the water level daily to ensure the pump will remain submerged. Add water if necessary.
3. Clean the pump periodically to prevent mineral deposits and contamination.
4. Disassemble the unit to clean any build up of debris inside the impeller and rotor.
5. Do not operate this pump below 0
°
C, otherwise Freezing damage May Occur. If temperature is likely to fall below 0
°
C remove the pump from the pond, ensure all water is
removed from the pump and the unit is completely dry and stored in a frost-free place.
SAFETY
These pumps are carefully inspected and tested to ensure both safety and operating performance. However, failure to follow the instructions and warnings in this guide may result in pump
damage and/or serious injury. There will be no liability for any damage resulting from failure to observe this guide’s instructions.
1. To reduce risk of electric shock, always disconnect the pump from the electrical supply before handling or cleaning the pump.
2. To reduce risk of electric shock, inspect the pump and cord for damage before installation or maintenance
replace pump if damage is found.
3. Do not exceed voltage indicated on the label. Pump must be connected to an approved ground fault circuit interrupter (GFCI) receptacle.
4. Always keep the cord away from high temperature.
5. To achieve best performance, the pump should be placed on a flat surface and completely submerged in the water.
LIMITED WARRANTY
This pump is warranted to the original user against defective materials and workmanship for a period of 12 months. Our limited warranty does not cover any costs associated with the
installation or removal of products subject to warranty claims or the cost of return of the pump. The warranty will commence from the date of purchase. Replacement liability is limited
to any part or parts of the unit which have failed due to defective material or workmanship. Proof of purchase is required for all claims against the limited warranty. This warranty does
not extend to damage of the product or part resulting from accident, misuse, alteration, neglect, abuse, improper installation or normal wear and tear to the product(s). This limited
warranty extends only to the original user of the product.
For more information on this and other products, please visit our web site:
www.angelodecor.com
To contact us regarding this unit, your options include:
Email:customersupport@angelodecor.com | Phone: (780) 453 - 6646 | Fax: (780) 453- 6620
Angelo Décor International Inc. | 15840 118
th
Avenue | Edmonton, AB |T5V 1C4
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1

FOUNTAIN PUMP / Instruction Manual SP450 / SP550 / SP650 / SP850 / SP900 / SP1200 / SP1500 / SP1800 / SP2200 PRINTED IN CHINA SP112013 IMPORTANT!

Seite 2

POMPE FONTAINE / Manuel d'instruction SP450 / SP550 / SP650 / SP850 / SP900 / SP1200 / SP1500 / SP1800 / SP2200 IMPRIMÉ EN CHINE SP112013 IMP

Kommentare zu diesen Handbüchern

Keine Kommentare